Amprobe-310 Motor Maintenance HVAC Clamp Meter

Amprobe-310 Motor Maintenance HVAC Clamp Meter

Good
Out of Stock
Brand:Amprobe
Branch: Industrial Grade
Category: Clamp Meters

Fast Delivery

Receive in amaizing time

Easy Return

Return policy that lets you shop at ease

Always Authentic Products

We only sell 100% authentic products

Secure Shopping

Your data is always protected

Overview
Specifications
Features
Reviews

Whether you would like associate amp clamp for HVAC, general electrical or motor testing applications, the AMP-310 Clamp Meter, with its giant backlit show, has the options you would like. HVAC technicians can realize the temperature and capacitance measurements they have and DC Microamps for testing flame sensors.

It also had core motor testing capabilities such as motor rotation, 3-phase sequence testing, and inrush current measurement for motor start-up monitoring. The low pass filter permits you to accurately live current and voltage on variable frequency drives.

The Amp-Tip perform permits for the precise activity of current right down to the tenth of associate Amp, facultative correct current activity of each giant and little diameter wires. It also offers a full range of standard multimeter features, including AC current, AC/DC voltage, frequency, True-RMS, non-contact voltage detection, resistance, continuity and a CAT III 600 V safety rating.

AC voltage (True-rms) Range: 0 to 600.0 V 0 to 1000.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz) ±0.8% + 5LSD (50 to 60 Hz)
DC voltage Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
AC+DC voltage Range: 0 to 600.0 V 0 to 600.0 V 0 to 1000.0 V
Accuracy: ±1.2% + 7LSD (50 to 60 Hz) ±1.2% + 7LSD (50 to 60 Hz) ±1.0% + 7LSD (50 to 60 Hz) 
±1.8% + 7LSD (DC 40 to 200 Hz) 
±1.2% + 7LSD 200 to 400 Hz)
AC current Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 60 Hz) 
±2.0% + 5LSD (100 to 400 Hz)
DC current Range: 0 to 600.0 A 0 to 600.0 A 0 to 1000.0 A
Accuracy: ±2.0% + 5LSD (DC 50 to 100 Hz) ±2.0% + 5LSD (DC 50 to 100 Hz) ±1.8% + 5LSD (DC 50 to 100 Hz)
AC+DC current Range: 0 to 600.0 A 0 to 600.0 A 0 to 1000.0 A
Accuracy: ±2.2% + 7LSD (DC 50 to 100 Hz) 
±2.7% + 7LSD (100 to 400 Hz)
±2.2% + 7LSD (DC 50 to 100 Hz) 
±2.7% + 7LSD (100 to 400 Hz)
±2.2% + 7LSD (40 to 100 Hz) 
±2.5% + 7LSD (100 to 400 Hz)
Precise low current AC Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz) ±1.5% + 5LSD (50 to 60 Hz) 
±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz) 
±3.0% + 5LSD (>20.00 to 60.00 A, 40 to 100 Hz) 
±3.0% + 5LSD (>20.00 to 60.00 A, 100 to 100 Hz)
Precise low current DC Range: 0 to 60.0 A 0 to 60.0 A 0 to 60.00 A
Accuracy: ±2.0% + 5LSD ±2.0% + 5LSD ±1.5% + 5LSD (0.00 to 20.00 A) 
±3.0% + 5LSD (>20.00 to 60.00 A)
Micro amps Range: 0 to 2000 µA
Accuracy: ±1.0% + 5LSD
Frequency Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±2.0% + 4LSD (600 A range)
Resistance Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Capacitance Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
Continuity beeper ON ≤ 10 Ω
Off > 250 Ω
Temperature* 
(Type K thermocouple)
  -40.0 to 752 °F
-40.0 to 400 °C
  ±1.0% + 3.0 °F (-40.0 to 14.0 °F) 
±1.0% + 1.5 °F (>40.0 to 99.9 °F) 
±1.0% + 2.0 °F (100 to 752 °F) 
±1.0% + 1.5 °C (-40.0 to 10.0 °C) 
±1.0% + 0.8 °C (>-10.0 to 99.9 °C) 
±1.0% + 1.0 °C (100 to 400 °C) 
Non-contact voltage 10 V to 1000 V AC (50 to 60 Hz)
Phase rotation indication   Rotation-R for main supply 
Rotation-M for motors
Diode test  
Jaw opening   1.18 in (30 mm) 1.37 in (35 mm) 1.18 in (30 mm) 1.37 in (35 mm) 2.0 in (51 mm)
Safty rating   CAT III 600 V CAT IV 600V 
CAT III 1000 V
Special Features
In-rush current  
Peak hold (Crest)  
Relative zero  
Max/Min/Avg  
Data hold  
Backlight  
Auto power off  
Work light  
  • Measures AC Current to 600 A and AC/DC Voltage to 600 V
  • Measures temperature from -40° to 752°F, (-40° to 400°C)
  • Measures DC Microamps output to test proper operation of the flame sensor on gas appliances
  • Measures capacitance, test diodes, and features a continuity beeper
  • Tests 3-phase sequence and motor rotation to ensure proper connection of a motor to a 3-phase system
  • Provides resistance and continuity measurement capabilities to verify the quality of electrical connections and the proper operation of motor and transformer coils
  • Includes test leads, batteries (installed), alligator clip set, banana plug K-type thermocouple, carrying case, and user manual
  • Backlit display for easy measurement viewing in bright and dim environments
  • Monitors inrush current during motor start-up
  • Features True-RMS sensing for accurate voltage measurements in noisy electrical environments
  • Amp-Tip function delivers precise low AC current measurements – 0 to 60 A
  • Includes a low pass filter to accurately measure voltage and current on variable frequency drives
  • Provides data hold, relative zero, and MAX/MIN/AVG mode for quick analysis
  • Maximizes battery life with auto power off and low battery indicator
  • CAT III 600 V safety rated
  • Accommodates conductors up to 1.18 inches (30 mm)

Trending Items

Fluke 115 True-RMS Digital Multimeter

Fluke 115 True-RMS Digital Multimeter

Good
Fluke Ti400 Thermal scanning Camera

Fluke Ti400 Thermal scanning Camera

Good
Fluke 376 True RMS AC/DC Clamp Meter

Fluke 376 True RMS AC/DC Clamp Meter

Good
Fluke TiS20+ MAX Thermal Scanner

Fluke TiS20+ MAX Thermal Scanner

Good

You May Like Also

Amprobe ACD-20SW Clamp Meter

Amprobe ACD-20SW Clamp Meter

Good
Fluke 375 True RMS AC/DC Clamp Meter

Fluke 375 True RMS AC/DC Clamp Meter

Good
Fluke 368 FC Leakage Current Clamp Meter

Fluke 368 FC Leakage Current Clamp Meter

Good
Fluke 373 True-RMS AC Clamp Meter

Fluke 373 True-RMS AC Clamp Meter

Good