Fluke 1630-2 FC Earth Ground Clamp

Fluke 1630-2 FC Earth Ground Clamp

Good
Out of Stock
Brand:Fluke
Branch: Industrial Grade

Fast Delivery

Receive in amaizing time

Easy Return

Return policy that lets you shop at ease

Always Authentic Products

We only sell 100% authentic products

Secure Shopping

Your data is always protected

Overview
Specifications
Features
Resources
Reviews

Fluke 1630-2 FC Earth Ground Clamp

Test the grounding parts of the apparatus in hard-to-reach areas, together with areas that are inside or totally paved and don't allow driving auxiliary check stakes. Stay online—identify mishap resistance while not the requirement to disconnect then reconnect the planet conductor from the system.

The Fluke 1630-2 FC earth Ground Clamp is that the quite high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in standardization even in daily, on-the-job industrial environments.

This earth ground clamp meter not only shows the accurate result but also the value of this meter always spot on.

Electrical Specifications
Maximum voltage to earth ground 1000 V
Battery type AA alkaline IEC/EN LR6 (x4)
Battery life More than 15 hours*
* In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off
Frequency range 40 Hz to 1 kHz
Ingress protection IEC/EN 60529: IP30 with jaw closed
LCD Digital reading 9999 counts
Refresh rate 4 per second
Operating temperature -10 °C to + 50 °C  
Storage temperature -20 °C to + 60 °C
Operating humidity Non condensing (<10 °C) (< 50 °F)  
≤90% RH (at 10 °C to 30 °C [50 °F to 86 °F])
≤75% RH (at 30 °C to 40 °C [86 °F to 104 °F]) 
≤45% RH (at 40 °C to 50 °C [104 °F to 122 °F])
(Non condensing)
Operating altitude 2000 m (6561 feet)
Storage altitude 12 000 m (39,370 feet)
Reference temperature 23 °C ±5 °C (73 °F ±9 °F)
Temperature coefficient 0.15% x (specified accuracy)/ °C (<18 °C or >28 °C [<64.4 °F or >82.4 °F])
Overload indication OL
Data logging capacity Minimum of 32,760 measurements
Data logging interval 1 second to 59 minutes and 59 seconds
Display reading specification with standard loop resistance
Input (Ω) Minimum Maximum
0.474 0.417 0.531
0.5 0.443 0.558
10 9.55 10.45
100 96 104
Safety
General IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1
Measurement IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V
Current clamp for leakage current measurements IEC/EN 61557-13: Class 2, ≤30 A/m
Resistance to earth IEC/EN 61557-5
Effectiveness of thepProtective measures IEC/EN 61557-16
Electromagnetic compatibility (EMC) International IEC/EN 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class B, IEC/EN 61326-2-2
Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Wireless Radio
Frequency range 2412 MHz to 2462 MHz
Output power <10 mW
Radio frequency certification FCC ID:T68-FBLE IC:6627A-FBLE
General Specifications
Conductor size 40 mm (1.57 in) approximately
Dimensions (L x W x H) 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in)
Weight 880g (31 oz)
Warranty One year
Earth Ground Loop Resistance
Range Accuracy1  ± (% of reading + Ω)
0.025 Ω to 0.249 Ω 1.5% + 0.02 Ω
0.250 Ω to 0.999 Ω 1.5% + 0.05 Ω
1.000 Ω to 9.999 Ω 1.5% + 0.10 Ω
10.00 Ω to 49.99 Ω 1.5% + 0.30 Ω
50.00 Ω to 99.99 Ω 1.5% + 0.50 Ω
100.0 Ω to 199.9 Ω 3.0% + 1.0 Ω
200.0 Ω to 399.9 Ω 5.0% + 5.0 Ω
400 Ω to 599 Ω 10.0% + 10 Ω
600 Ω to 1500 Ω 20.00%
1  Loop resistance with no inductance, conductor centered and perpendicular to jaw
Earth ground leakage current mA
Autorange 50/60 Hz, True rms, crest factor CF ≤3
Range Resolution Accuracy1  ± (% of reading + mA)
0.200 mA to 3.999 mA 1 μA 2.0% + 0.05 mA
4.00 mA to 39.99 mA 10 μA 2.0% + 0.03 mA
40.0 mA to 399.9 mA 100 μA 2.0% + 0.3 mA
0.400 A to 3.999 A 1 mA 2.0% + 3 mA
4.00 A to 39.99 A 10 mA 2.0% + 30 mA
1 Applies to signal frequency
  • 40 Hz to 1 kHz with filter set to OFF
  • 40 Hz to 70 Hz with filter se to ON
  • 3- and 4-Pole Fall-of-Potential (using stakes)
  • Selective Testing (using 1 clamp and stakes)
  • Stakeless Testing (using 2 clamps only)
  • 4-Pole Soil Resistivity Testing (using stakes)

Trending Items

Fluke 115 True-RMS Digital Multimeter

Fluke 115 True-RMS Digital Multimeter

Good
Fluke Ti400 Thermal scanning Camera

Fluke Ti400 Thermal scanning Camera

Good
Fluke 376 True RMS AC/DC Clamp Meter

Fluke 376 True RMS AC/DC Clamp Meter

Good
Fluke TiS20+ MAX Thermal Scanner

Fluke TiS20+ MAX Thermal Scanner

Good

You May Like Also

Fluke 1630-2 FC Earth Ground Clamp

Fluke 1630-2 FC Earth Ground Clamp

Good
Fluke 1623-2 GEO Earth Ground Resistance Meter

Fluke 1623-2 GEO Earth Ground Resistance Meter

Good
Fluke 1625-2 GEO Earth Ground Tester

Fluke 1625-2 GEO Earth Ground Tester

Good
Fluke 1621 GEO Earth Ground Tester

Fluke 1621 GEO Earth Ground Tester

Good