Fluke 1625-2 GEO Earth Ground Tester

Fluke 1625-2 GEO Earth Ground Tester

Good
Out of Stock
Brand:Fluke
Branch: Industrial Grade

Fast Delivery

Receive in amaizing time

Easy Return

Return policy that lets you shop at ease

Always Authentic Products

We only sell 100% authentic products

Secure Shopping

Your data is always protected

Overview
Specifications
Features
Resources
Reviews

Fluke 1625-2 GEO Earth Ground Tester offers quick, correct earth ground checking victimization all four test ways.

The Fluke 1625-2 earth ground tester measures earth mishap resistances victimization solely clamps, solely stakes, or one clamp and stakes. With the stakeless check methodology, the Fluke 1625-2 is in a position to live earth mishap resistances for multi-grounded systems victimization solely current clamps. this method eliminates the harmful, and time intense job of disconnecting parallel grounds, and finding appropriate locations for auxiliary ground stakes. this enables you to perform earth ground tests in places you’ve not thought about before, like within buildings, on power pylons, or anyplace you don’t have access to soil.

Keep your choices open if a secure earth ground system doesn't exist for the building or structure underneath check, and there's only 1 path to ground, you'll use the 1625-2 to perform the fall-of-potential check methodology with stakes.

Other useful capabilities:

  • Provides R* measurement that calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see
  • Includes USB port for data storage and transfer
  • Features IP56 rating for outdoor use
  • Offers adjustable limits for quicker testing
  • Comes with a rugged carrying case

We Fluke Bangladesh owned and operated by Iconic Engineering limited. We are the sole distributor of Fluke. One of the best things about us that not only we provide the right tools but also we always support our customers all the time. 

Specifications: Fluke 1625-2 GEO Earth Ground Tester

General Specifications
Memory Internal memory storage up to 1500 records accessible via USB port
Measuring function Interference voltage and frequency, earthing resistance 3- and 4-pole with/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC
Display 4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility
Operation Central rotary switch and function keys
Temperature Range
Operating temperature -10°C to 50°C (14°F to 122°F)
Storage temperature -30°C to 60°C (-22°F to 140°F)
Temperature coefficient ±0.1% of reading/°C < 18°C > 28°C
Type of protection IP56 for case, IP40 for battery door according to EN60529
Max voltage Warning – socket "clamp" to socket E, ES, S or H
Urms = 0 V
Sockets E, ES, S or H to each other in any combination, max. Urms = 250 V (pertains to misuse)
Safety Protection by double and/or reinforced insulation. Max. 50 V to earth per IEC61010-1. 300 V CAT II, Pollution degree 2
Quality standard Developed, designed and manufactured to comply with DIN ISO 9001
External field influence Complies with DIN 43780 (8/76)
Auxiliary power 6 x 1.5 V alkaline (IEC LR6 or type AA)
Battery life span With IEC LR6/type AA: typ. 3,000 measurements (RE+RH ≤ 1 kΩ)
With IEC LR6/type AA: typ. 6,000 measurements (RE + RH > 10 kΩ)
Dimensions (W x H x D) 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)
Weight ≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case
Case material Polyester
Measurement of Interference Voltage DC + AC (UST)
Measuring limits of error: method Full wave rectification
Measuring range 1 V to 50 V
Display range 0.0 V to 50 V
Resolution 0.1 V
Frequency range DC/AC 45 Hz to 400 Hz sine
Accuracy ±(5% of rdg + 5 digit)
Measuring sequence Approx. 4 measurements/s
Internal resistance Approx. 1.5 MΩ
Max. overload Urms = 250 V
Measurement of Interference Frequency (F)
Measuring limits of error: method Measurement of oscillation period of the interference voltage
Measuring range 6.0 Hz to 400 Hz
Display range 16.0 Hz to 299.9 Hz to 999 Hz
Resolution 0.1 Hz to 1 Hz
Range 1 V to 50 V
Accuracy ±(1% of rdg + 2 digit)
Earthing Resistance (RE)
Measuring method Current and voltage measurement with probe as IEC61557-5
Open circuit voltage 20/48 V, AC
Short circuit current 250 mA AC
Measuring frequency 94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R1
Noise rejection 120 dB (16 2/3 , 50 , 60, 400 Hz)
Max. overload Urms = 250 V
Electrical Measurement Specifications
Intrinsic Error or Influence Quantity Reference Conditions or Specified Operating Range Designation Code Requirements or Test in Accordance with the Relevant Parts of IEC 1557 Type of Test
Intrinsic error Reference conditions A Part 5, 6.1 R
Position Reference position ±90° E1 Part 1, 4.2 R
Supply voltage At the limits stated by the manufacturer E2 Part 1, 4.2, 4.3 R
Temperature 0°C and 35°C E3 Part 1, 4.2 T
Series interference voltage See 4.2 and 4.3 E4 Part 5, 4.2, 4.3 T
Resistance of the probes and auxiliary earth electrodes 0 to 100 x RA but ≤ 50 kΩ E5 Part 5, 4.3 T
System frequency 99% to 101% of the nominal frequency E7 Part 5, 4.3 T
System voltage 85% to 110% of the nominal voltage E8 Part 5, 4.3 T
Operating error B = ±(|A| + 1,15 √E21 E22 E23 E24 E25 E2) Part 5, 4.3 R
B[%] = ± B/fiducial value x 100%

A = intrinsic error
En = variations
R = routine test
T = type test
Measuring range 0.020 Ω to 300 kΩ
Display range 0.001 Ω to 2.999 Ω
3.00 Ω to 29.99 Ω
30.0 Ω to 299.9 Ω
0.300 kΩ to 2.999 kΩ
3.00 kΩ to 29.99 kΩ
30.0 kΩ to 299.9 kΩ
Resolution 0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
100 Ω
Accuracy ±(2% of rdg + 2 digit)
Operating error ±(5% of rdg + 5 digit)
Measuring time Typical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies
Additional error because of probe-and auxiliary earth electrode resistance RH(RS + 2000 Ω)/RE x 1.25 x 10-6% + 5 digits
Measuring error of RH and RS Typ. 10% of RE + RS + RH
Max. probe resistance ≤ 1 MΩ
Max. auxiliary earth electrode resistance ≤ 1 MΩ

Automatic check if error is kept within the limits required by IEC61557-5.
If after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.

Automatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance RH
RH with Umeas = 48 V < 300 Ω
< 6 Ω
< 60 Ω
< 600 Ω
RH with Umeas = 20 V < 250 Ω
< 2.5 kΩ
< 25 kΩ
< 250 kΩ
Resolution 1 mΩ
10 mΩ
100 mΩ
1 Ω
Selective Measurement of the Earthing Resistance (RE Clamp)
Measuring method Current and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).
Open circuit voltage 20/48 V AC
Short circuit current 250 mA AC
Measuring frequency 94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R1)
Noise rejection 120 dB (162/3, 50, 60, 400 Hz)
Max. overload Max. Urms = 250 V (measurement will not be started)
Measuring range 0.020 Ω to 300 kΩ
Display range 0.001 Ω to 2.999 Ω
3.00 Ω to 29.99 Ω
30.0 Ω to 299.9 Ω
0.300 kΩ to 2.999 kΩ
3.00 kΩ to 29.99 kΩ
Resolution 0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
Accuracy ±(7% of rdg + 2 digit)
Operating error ±(10% of rdg + 5 digit)
Additional error because of probe- and auxiliary earth typ. electrode resistance RH(RS + 2000 Ω)/RETOTAL x 1.25 x 10-6% + 5 digits
Measuring error of RH and RS Typ. of 10% of RETOTAL + RS + RH
Measuring time Typ. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.
Minimal current in single branch to be measured 0.5 mA With transformer (1000:1)
0.1 mA With transformer (200:1)
Max. interference current through transformer 3 A With transformer (1000:1)
1. With recommended current clamps/transformers.
Resistance Measurement (R~)
Measuring method Current and voltage measurement
Measuring voltage 20 V AC, square pulse
Short circuit current > 250 mA AC
Measuring frequency 94, 105, 111, 128 Hz selected manually or automatically (AFC)
Measuring range 0.020 Ω to 300 kΩ
Display range 0.001 Ω to 2.999 Ω
3.00 Ω to 29.99 Ω
30.0 Ω to 299.9 Ω
300 Ω to 2999 Ω
3.00 kΩ to 29.99 kΩ
30.0 kΩ to 299.9 kΩ
Resolution 0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
100 Ω
Accuracy ±(2% of rdg + 2 digit)
Operating error ±(5% of rdg + 5 digit)
Measuring time Typical 6 seconds
Max. interference voltage 24 V, with higher voltages measurement will not be started
Max overload Urms max. = 250 V
Resistance Measurement (R DC)
Measuring method Current- voltage measurement as per IEC61557-4 possible
Measuring voltage 20 V DC
Short circuit current 250 mA DC
Formation of measured value With 4-pole measurement wires on H, S, ES can be extended without additional error.
Resistances > 1 Ω in wire E can cause additional error of 5m Ω/Ω.
Measuring range 0.020 Ω to 300 kΩ
Display range 0.001 Ω to 2.999 Ω
3.00 Ω to 29.99 Ω
30.0 Ω to 299.9 Ω
300 Ω to 2999 Ω
3.0 kΩ to 29.99 kΩ
30.0 kΩ to 299.9 kΩ
Resolution 0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
100 Ω
Accuracy ±(2% of rdg + 2 digit)
Operating error ±(5% of rdg + 5 digit)
Measuring sequence Approx. 2 measurements/s
Measuring time Typical 4 second including reversal of polarity (2-pole or 4-pole)
Maximum interference voltage ≤ 3 V AC or DC, with higher voltages measurement will not be started
Maximum inductivity 2 Henry
Maximum overload Urms = 250 V
Compensation of Lead Resistance (RK)
Compensation of lead resistance (RK) can be switched on in functions RE 3-pole, RE 4-pole (clamp), R AC, and R DC 2-pole
Formation of measured value Rdisplay = Rmeasured - Rcompensated2
2. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.
Stakeless Ground Loop Measurement (Two Clamp Stakeless)
Switch position RA 4-pole (two clamp Stakeless)
Resolution 0.001 Ω to 0.1 Ω
Measuring range 0.02 Ω to 199.9 Ω
Accuracy ±(7% rdg + 3 digit)
Operating error ±(10% rdg + 5 digit)
Measuring voltage Vm = 48 V AC (primary)
Measuring frequency 128 Hz
Noise current (IEXT) Max. IEXT = 10 A (AC) (RA < 20 Ω)
Max. IEXT = 2 A (AC) (RA > 20 Ω)
Measuring principle: Stakeless measurement of resistance in closed loops using two current transformers.
Automatic range selection.
The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.

Key features of Fluke 1625-2 GEO earth ground tester

  • A unique earth ground tester that performs testing with and without stakes
  • Tests 3- and 4-pole fall-of-potential, and 4-pole soil resistivity (with stakes)
  • Features Automatic Frequency Control (AFC) to minimize the effect of interference
  • Performs stakeless earth ground rod testing (two clamps)
  • Performs selective earth ground rod testing (one clamp + stakes)

Trending Items

Fluke 115 True-RMS Digital Multimeter

Fluke 115 True-RMS Digital Multimeter

Good
Fluke Ti400 Thermal scanning Camera

Fluke Ti400 Thermal scanning Camera

Good
Fluke 376 True RMS AC/DC Clamp Meter

Fluke 376 True RMS AC/DC Clamp Meter

Good
Fluke TiS20+ MAX Thermal Scanner

Fluke TiS20+ MAX Thermal Scanner

Good

You May Like Also

Fluke 1621 GEO Earth Ground Tester

Fluke 1621 GEO Earth Ground Tester

Good
Fluke 1623-2 GEO Earth Ground Resistance Meter

Fluke 1623-2 GEO Earth Ground Resistance Meter

Good
Fluke 1625-2 GEO Earth Ground Tester

Fluke 1625-2 GEO Earth Ground Tester

Good
Fluke 1630-2 FC Earth Ground Clamp

Fluke 1630-2 FC Earth Ground Clamp

Good